10-19-2-proverka-i-zamena-datchika-ukazatelya-temperatury-okhlazhdayushhejj-zhidkosti.html
10.19.2. Check and replacement of the sensor of the index of temperature of cooling liquidIt will be required to you: a high face head "on 13", the extender, a tester.
1. Disconnect a wire from the minus plug of the rechargeable battery.
|
|
3. Disconnect a wire from the sensor, having shifted a block of a plait of wires back.
|
4. Weaken a sensor inhaling …
|
|
|
5. … also turn out it from an inlet pipe.
|
6. For check connect a tester in the ohmmeter mode to a conclusion and the case of the sensor. Sensor resistance at the room temperature has to make 0,7–0,8 kOhm.
|
7. For measurement of resistance on sensor conclusions at various temperature conditions lower the sensor in hot water and track change of its resistance in process of water cooling: it has to increase. If the sensor does not react to change of temperature, then it needs to be replaced.
8. Establish details as it should be, the return to removal.
|