4-3-11-proverka-i-regulirovka-privoda-vyklyucheniya-scepleniya.html
4.3.11. Check and adjustment of the drive of switching off of couplingIt will be required to you: keys "on 7", "on 12", "on 13" (two), the screw-driver, a ruler.
|
|
1. To measure a full speed of a pedal of coupling, measure distance from an overlay of a pedal to a floor, without pressing a pedal.
|
2. Press a pedal against the stop and repeat measurement. The difference between two measurements is also a full speed of a pedal of coupling which nominal rate of 130-136 mm. If the course of a pedal differs from nominal rate, it needs to be adjusted.
|
3. Weaken on pedal knot an inhaling of a lock-nut of an adjusting bolt a key and rotation of a bolt achieve the required value of a full speed of a pedal, tighten a lock-nut.
4. To define a free wheeling of a pedal of coupling, measure distance from the initial provision of a pedal to situation in which when pressing a pedal increase in resistance is felt as a hand. Nominal free wheeling of a pedal of coupling of 8-15 mm. If the free wheeling differs from nominal rate, adjust length of a pusher of the main cylinder of coupling for what …
|
|
5. … weaken a lock-nut inhaling …
|
6. … and, rotating a pusher for a lyska, adjust a free wheeling of a pedal, tighten a lock-nut.
|
|
|