5-16-2-snyatie-proverka-i-ustanovka-pnevmaticheskogo-klapana-recirkulyacii-otrabotavshikh-gazov.html
5.16.2. Removal, check and installation of the pneumatic valve of recirculation of the fulfilled gasesYou will need a key "on 12".
|
|
1. Disconnect a vacuum hose from the pneumatic valve of recirculation of the fulfilled gases.
|
2. Turn out two bolts of fastening of the valve to an inlet pipe …
|
3. … also remove the valve.
NOTE
Connection of the valve with an inlet pipe is condensed with laying. At each dismantling of connection replace sealing laying new.
|
4. For valve check give in any way depression to its vacuum chamber and watch movement of a plunger (it is shown by an arrow). If the plunger remains motionless, replace the valve.
5. Install the pneumatic valve of recirculation of the fulfilled gases as it should be, the return to removal.
|